NEOPLAN USA CORPORATION: Safety Recalls in 2005

Updated on March 19, 2026.

There were 4 safety recalls made by NEOPLAN USA CORPORATION in 2005. See the details of the recalls below.

You can also see similar information for other manufacturers.

Data Source: NHTSA.
See this for other years:
July 14, 2005
(Campaign #: NR (Not Reported))

DOOR ASSEMBLIES/VAPOR

ON CERTAIN TRANSIT BUSES EQUIPPED WITH VAPOR DOOR ASSEMBLIES, THE TWO PIECE CURVED CONNECTING RODS WHEN USED AS AN ELEMENT OF THE DOOR ACTUATION LINKAGE IN CONJUNCTION WITH A VAPOR MEDIUM PNEUMATIC DIFFERENTIAL ENGINE, MAY BE SUBJECT TO FATIGUE FAILURE RESULTING IN BENDING OR BREAKING OF THE CONNECTING ROD.
NHTSA ID: 05V321000
Component: STRUCTURE
# of Units Affected: 311
Consequence Summary:
A BROKEN CONNECTING ROD CAN ALLOW THE DOOR PANEL TO MOVE FREELY IN AN UNCONTROLLED MANNER, LEAVING PASSENGERS INSIDE THE VEHICLE UNPROTECTED BY THE DOOR PANEL AND ENABLING A PROTRUDING DOOR PANEL TO STRIKE PERSONS OR OBJECTS OUTSIDE THE VEHICLE.
Corrective Action:
NEOPLAN IS WORKING WITH VAPOR BUS INTERNATIONAL TO NOTIFY OWNERS AND HAVE THE REPAIR PERFORMED ON THEIR VEHICLES. THE REMEDY CONSISTS OF REPLACING THE TWO PIECE CONNECTING ROD WITH A ONE PIECE CONNECTING ROD. OWNERS MAY CONTACT VAPOR AT 1-847-777-6400 OR NEOPLAN AT 1-719-336-3256.
Park Outside Advisory: No
Do not Drive Advisory: No
June 14, 2005
(Campaign #: NR (Not Reported))

ENGINE TURBOCHARGER/SERIES 50/DETROIT DIESEL

ON CERTAIN STANDARD FLOOR, LOW FLOOR AND ARTICULATED TRANSIT BUSES BUILT WITH DETROIT DIESEL SERIES 50 ENGINES, THE TURBOCHARGER COMPRESSOR WHEEL CAN BREAK, RESULTING IN SHAFT IMBALANCE AND LUBRICATING OIL PASSES INTO THE EXHAUST SYSTEM.
NHTSA ID: 05V290000
Component: ENGINE AND ENGINE COOLING
# of Units Affected: 465
Consequence Summary:
THIS CAN RESULT IN AN ENGINE COMPARTMENT FIRE, POSSIBLY RESULTING IN PERSONAL INJURIES.
Corrective Action:
NEOPLAN IS WORKING WITH DETROIT DIESEL TO NOTIFY OWNERS AND HAVE THE REPAIR PERFORMED ON THEIR VEHICLES. DEALERS WILL INSTALL AN EXHAUST TEMPERATURE SENSOR AND REPROGRAM THE EMC CALIBRATION. OWNERS MAY CONTACT NEOPLAN AT 719-336-3256 OR DETROIT DIESEL AT 313-592-3708.
Park Outside Advisory: No
Do not Drive Advisory: No
June 7, 2005
(Campaign #: FSRP 04-092)

STARTER CABLE

ON CERTAIN 60' ARTICULATED TRANSIT BUSES, THE STARTER CABLE AND ADDITIONAL HEAVY GAUGE WIRES HAD INADVERTENTLY BEEN ATTACHED TO THE STARTER STUD DURING THE MANUFACTURING AND ASSEMBLY PROCESS.
NHTSA ID: 05V267000
Component: ELECTRICAL SYSTEM
# of Units Affected: 85
Consequence Summary:
OVER TIME, THE STARTER SOLENOID COULD CRACK AND A SHORT CIRCUIT MIGHT DEVELOP THAT WOULD RESULT IN A VEHICLE FIRE.
Corrective Action:
THESE VEHICLES WERE SENT TO ONLY ONE CUSTOMER, NEW JERSEY TRANSIT. ALL VEHICLES HAVE BEEN CORRECTED.
Park Outside Advisory: No
Do not Drive Advisory: No
March 1, 2005
(Campaign #: 08-314)

TIE ROD CLAMPS/ARVINMERITOR/URRESKO

ON CERTAIN TRANSIT BUSES EQUIPPED WITH ARVINMERITOR URRESKO TIE ROD CLAMPS, HEAT TREATMENT OF CLAMPS CREATED A SURFACE HARDNESS THAT COULD LEAD TO A FRACTURE OF THE CLAMPS.
NHTSA ID: 05V068000
Component: STEERING
# of Units Affected: 175
Consequence Summary:
IN THE EVENT OF A CRACK, THE CLAMPS COULD BREAK OFF AFFECTING TOE-IN AND ALIGNMENT. THE TIE ROD CAN COME LOOSE RESULTING IN STEERING LOSS AND A CRASH COULD OCCUR WITHOUT PRIOR WARNING.
Corrective Action:
ARVINMERITOR IS CONDUCTING THE OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN. OWNERS MAY CONTACT ARVINMERITOR AT 1-866-668-7221 OR NEOPLAN AT 719-336-3256.
Park Outside Advisory: No
Do not Drive Advisory: No