Wilson Manifolds Inc: Safety Recalls in 2016

Updated on March 19, 2026.

There was 1 safety recall made by Wilson Manifolds Inc in 2016. See the detail of the recall below.

You can also see similar information for other manufacturers.

Data Source: NHTSA.
June 13, 2016
(Campaign #: NR (Not Reported))

Nitrous Solenoid Valve Not Welded Correctly

Wilson Manifolds Inc. (Wilson) is recalling certain Peter Paul 22X01031GM 12/DC solenoid valves manufactured May 1, 2015, to July 30, 2015. Due to improper welding, the affected valves may separate when under pressure either during installation or during use of the nitrous system resulting in the piston ejecting.
NHTSA ID: 16E056000
Component: FUEL SYSTEM, OTHER
# of Units Affected: 55
Consequence Summary:
If the piston ejects, it can increase the risk of injury to those nearby or possibly damage other nearby components.
Corrective Action:
Wilson has notified owners, and has provided replacement solenoid valve stems, free of charge. The recall began on September 23, 2016. Owners may contact Wilson customer service at 1-954-771-6216.
Park Outside Advisory: No
Do not Drive Advisory: No
Completion Rate (%): 0