UCI International LLC: Safety Recalls in 2009
Updated on March 19, 2026.
There was 1 safety recall made by UCI International LLC in 2009. See the detail of the recall below.
You can also see similar information for other manufacturers.
Data Source: NHTSA.
July 24, 2009
(Campaign #: FP072009-1)
AFTERMARKET FUEL PUMP
AIRTEX IS RECALLING 1,440 AFTERMARKET FUEL PUMPS, P/N E3944M, PRODUCED FROM JANUARY 2005 THROUGH JULY 2009, SOLD FOR USE ON MODEL YEAR 1997 SATURN VEHICLES. THE FUEL RETURN LINE AND FUEL VENT LINE ARE REVERSED.
NHTSA ID: 09E047000
Component: FUEL SYSTEM, OTHER
# of Units Affected: 1,440
Consequence Summary:
IN THE EVENT THAT A VEHICLE WITH THE SUBJECT FUEL PUMP IS INVOLVED IN A ROLL-OVER CRASH WITH A FULL OR OVER-FULL FUEL TANK, THE FUEL COULD DRAIN FROM THE TANK INTO THE ENGINE COMPARTMENT, POSSIBLY RESULTING IN A FIRE.
Corrective Action:
AIRTEX WILL NOTIFY OWNERS AND REPLACE THE RECALLED FUEL PUMPS WITH A PUMP THAT HAS BEEN CORRECTLY MANUFACTURED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON AUGUST 15, 2009. OWNERS MAY CONTACT AIRTEX AT 1-618-842-2111.
Park Outside Advisory: No
Do not Drive Advisory: No