Sutrak USA: Safety Recalls in 2013
Updated on March 19, 2026.
There was 1 safety recall made by Sutrak USA in 2013. See the detail of the recall below.
You can also see similar information for other manufacturers.
Data Source: NHTSA.
June 21, 2013
(Campaign #: NR (Not Reported))
HVAC System Fuse Holder may cause Voltage Spikes
Sutrak USA (Sutrak) is recalling certain HVAC Systems manufactured May 2012 through May 2013 used in DART 39000 buses manufactured by North American Bus Industries, Inc. The fuse holder inside the HVAC may allow voltage spikes, which may damage electrical components.
NHTSA ID: 13E035000
Component:
# of Units Affected: 154
Consequence Summary:
Damage to electrical components may result in a fire.
Corrective Action:
Sutrak has been working with the bus manufacturer and the affected fleet and will replace the fuse holders, free of charge. The recall is expected to begin in late June 2013. Owners may contact Sutrak at 1-303-287-2700.
Park Outside Advisory: No
Do not Drive Advisory: No