September 22, 1995
(Campaign #: NR (Not Reported))

FURNACE:RECREATIONAL VEHICLE

THE FURNACES WERE IMPROPERLY INSTALLED. A 1 1/4" MINIMUM OVERLAP BETWEEN THE CHAMBER EXHAUST TUBE AND THE VENT ASSEMBLY EXHAUST IS NEEDED FOR PROPER EXHAUST.
NHTSA ID: 95V181000
Component: EQUIPMENT
# of Units Affected: 100
Consequence Summary:
THIS CONDITION CAN LEAD TO CARBON MONOXIDE POISONING.
Corrective Action:
DEALERS WILL REPLACE THE FURNACE VENT ASSEMBLY.
Park Outside Advisory: No
Do not Drive Advisory: No
July 31, 1995
(Campaign #: NR (Not Reported))

ELECTRICAL SYSTEM:FUSE AND FUSE RECEPTICLE

A SOLDER BRIDGE ON THE PRINTED CIRCUIT BOARD WITHIN THE FUSE PANEL OF THE POWER CONVERTER PASSED UNDETECTED THROUGH A TEST FIXTURE AND BYPASSES THE FUSE PROTECTING THE CIRCUIT.
NHTSA ID: 95E016002
Component: ELECTRICAL SYSTEM
# of Units Affected: 12,945
Consequence Summary:
THIS SOLDER BRIDGE, WHEN COUPLED WITH A DEAD SHORT ELSE WHERE IN THE SYSTEM, CAN RESULT IN CIRCUIT OVERLOAD, OVERHEATING, AND EVEN FIRE, WITHOUT WARNING.
Corrective Action:
DETAILED TEST INSTRUCTIONS ARE BEING PROVIDED. IF A DEFECTIVE FUSE PANEL IS FOUND, A NEW REPLACEMENT PANEL WILL BE INSTALLED.
Park Outside Advisory: No
Do not Drive Advisory: No