MIRADA: Safety Recalls in 1995

Updated on March 19, 2026.

There were 4 safety recalls made by MIRADA in 1995. See the details of the recalls below.

You can also see similar information for other manufacturers.

Data Source: NHTSA.
June 16, 1995
(Campaign #: NR (Not Reported))

FUEL:CNG: PRESSURE RELIEF VALVE/DEVICE

SOME TEMPERATURE SENSITIVE TRIGGERS WERE NOT X-RAYED. THESE TRIGGERS COULD CONTAIN INTERNAL VOIDS THAT WOULD MAKE THE TRIGGERS SUSCEPTIBLE TO ADVANCED CREEP CAUSING FALSE ACTIVATION AND VENTING OF THE CNG.
NHTSA ID: 95E025000
Component: FUEL SYSTEM, OTHER
# of Units Affected: 15,590
Consequence Summary:
VENTING OF THE CNG COULD RESULT IN A FIRE.
Corrective Action:
MIRADA WILL REPLACE THE PRESSURE RELIEF DEVICES WITH THE NEWER DESIGN "GENERATION 2.5" PRESSURE RELIEF DEVICES.
Park Outside Advisory: No
Do not Drive Advisory: No
May 5, 1995
(Campaign #: NR (Not Reported))

FUEL:CNG: PRESSURE RELIEF VALVE/DEVICE

NON-STAINLESS STEEL BALLS (CHROME PLATED STEEL) IN THE THERMAL TRIGGER OF THE PRESSURE RELIEF DEVICE HAVE CORRODED CAUSING FALSE THERMAL ACTIVATION.
NHTSA ID: 95E014000
Component: FUEL SYSTEM, OTHER
# of Units Affected: 1,000
Consequence Summary:
THIS CONDITION CAN CAUSE A SUDDEN RELEASE OF CNG. IF CNG WERE RELEASED TO THE ENVIRONMENT AND AN IGNITION SOURCE WERE PRESENT, A FIRE COULD OCCUR.
Corrective Action:
MIRADA WILL REPLACE THESE PRESSURE RELIEF DEVICES WITH DEVICES WHICH HAVE STAINLESS STEEL BALLS.
Park Outside Advisory: No
Do not Drive Advisory: No
March 16, 1995
(Campaign #: NR (Not Reported))

FUEL:CNG: PRESSURE RELIEF VALVE/DEVICE

UPON EXPOSURE TO IMPURITIES IN THE NATURAL GAS FUEL IN COLD WEATHER, AN INTERNAL O-RING ON THESE DEVICES CAN BLISTER DURING DECOMPRESSION AFTER "FAST-FILL" REFUELING RESULTING IN SEAL LEAKAGE.
NHTSA ID: 95E005000
Component: FUEL SYSTEM, OTHER
# of Units Affected: 5,515
Consequence Summary:
INTERNAL DAMAGE TO THE O-RING SEAL COULD CAUSE A RELEASE OF CNG. IF CNG WERE RELEASED TO THE ENVIRONMENT AND AN IGNITION SOURCE WERE PRESENT, A FIRE COULD OCCUR.
Corrective Action:
DEALERS WILL REPLACE RECALLED UNITS WITH NEW DEVICES THAT ARE NOT SUSCEPTIBLE TO O-RING DAMAGE FROM NON-METHANE COMPONENTS OF THE GAS SUPPLY WHEN THE DEVICES ARE DEVELOPED.
Park Outside Advisory: No
Do not Drive Advisory: No
March 7, 1995
(Campaign #: NR (Not Reported))

FUEL:CNG: PRESSURE RELIEF VALVE/DEVICE

THE TORQUE PLUG ASSEMBLED INTO THE PRESSURE RELIEF DEVICE WAS NOT WELDED OR PINNED IN PRODUCTION. THE TIGHTENING OR TORQUING OF THE PRESSURE RELIEF DEVICE AS INSTALLED ON THE VEHICLE COULD CAUSE DAMAGE TO THE INTERNAL PARTS OF THE DEVICE.
NHTSA ID: 95E007000
Component: FUEL SYSTEM, OTHER
# of Units Affected: 6,000
Consequence Summary:
INTERNAL DAMAGE TO THE DEVICE COULD CAUSE A SUDDEN RELEASE OF CNG. IF CNG WERE RELEASED TO THE ENVIRONMENT AND AN IGNITION SOURCE WERE PRESENT, A FIRE COULD OCCUR.
Corrective Action:
MIRADA WILL REPLACE THESE PRESSURE RELIEF DEVICES WITH DEVICES WHICH HAVE THE TORQUE PLUG WELDED OR PINNED.
Park Outside Advisory: No
Do not Drive Advisory: No