GEORGIE BOY MFG., LLC: Safety Recalls in 1999

Updated on March 19, 2026.

There were 3 safety recalls made by GEORGIE BOY MFG., LLC in 1999. See the details of the recalls below.

You can also see similar information for other manufacturers.

Data Source: NHTSA.
See this for other years:
August 17, 1999
(Campaign #: NR (Not Reported))

GEORGIE BOY/FMVSS 105

VEHICLE DESCRIPTION: MOTOR HOMES BUILT ON A FORD CHASSIS. THE BRAKE SYSTEM WARNING INDICATOR LAMP IS NOT IN THE CORRECT POSITION IN THE INSTRUMENT CLUSTER. THIS DOES NOT MEET THE REQUIREMENTS OF FMVSS NO. 105, "HYDRAULIC BRAKE SYSTEMS."
NHTSA ID: 99V165008
Component: SERVICE BRAKES, HYDRAULIC
# of Units Affected: 146
Consequence Summary:
THE BULB/SOCKET ASSEMBLY MAY NOT FUNCTION PROPERLY.
Corrective Action:
DEALERS WILL PLACE THE BRAKE SYSTEM WARNING INDICATOR LAMP IN THE CORRECT POSITION.
Park Outside Advisory: No
Do not Drive Advisory: No
April 6, 1999
(Campaign #: NR (Not Reported))

GEORGIE BOY/FUEL TANK STRAPS

VEHICLE DESCRIPTION: MOTOR HOMES BUILT ON CHRYSLER M50 AND M60 CHASSIS. THE MAIN FUEL TANK IS SUPPORTED BY TWO METAL STRAPS. THESE SUPPORTING STRAPS CAN CORRODE OVER TIME AND ALLOW THE FUEL TANK TO FALL.
NHTSA ID: 99V068000
Component: FUEL SYSTEM, GASOLINE
# of Units Affected: 490
Consequence Summary:
THIS TYPE OF FAILURE PRESENTS A HAZARD OF FIRE AND EXPLOSION.
Corrective Action:
DEALERS WILL INSPECT THE FUEL TANK STRAPS AND WILL REPLACE ANY STRAPS THAT SHOW SIGNIFICANT LOSS OF INTEGRITY. DUE TO THE AGE OF THE CHASSIS, CHRYSLER NO LONGER PROVIDES REPLACEMENT FUEL TANK STRAPS. NEW REPLACEMENT STRAPS WILL BE FABRICATED FROM THE CHRYSLER DRAWINGS.
Park Outside Advisory: No
Do not Drive Advisory: No
March 3, 1999
(Campaign #: NR (Not Reported))

GEORGIE BOY/MAGNETEK/POWER CONVERTER

VEHICLE DESCRIPTION: RECREATIONAL VEHICLES EQUIPPED WITH 45 AMP MAGNETEK POWER CONVERTERS. A WEAKENED BYPASS CAPACITOR ON THE CONVERTER'S PRINTED CIRCUIT BOARD CAN CAUSE A BREAKDOWN OF THE CAPACITOR ALLOWING ELECTRICAL CURRENT LEAKAGE.
NHTSA ID: 98V240004
Component: ELECTRICAL SYSTEM
# of Units Affected: 133
Consequence Summary:
ELECTRICAL CURRENT LEAKAGE COULD RESULT IN A FIRE.
Corrective Action:
MAGNETEK IS REPLACING THESE POWER CONVERTERS.
Park Outside Advisory: No
Do not Drive Advisory: No