December 27, 2010
(Campaign #: 10-041-ACU)

TRANS/AIR TA-73 EVAPORATOR/OVERHEATS

CORP. MICRO BIRD IS RECALLING CERTAIN MODEL YEAR 1999 THROUGH 2002 GIRARDIN MB IV TRANSIT BUSES BUILT ON FORD AND GM CUTAWAY CHASSIS FROM AUGUST 2, 1999, THROUGH MAY 8, 2002, AND EQUIPPED WITH A TRANS/AIR TA73 EVAPORATOR. THE EVAPORATOR UTILIZES A POWER RESISTOR TO REGULATE BLOWER SPEED. SHOULD A SHORT OCCUR IN THE "LOW OR MEDIUM SPEED" CIRCUIT WHILE THE BLOWER IS IN HIGH SPEED, THE SHORT WILL CAUSE THE SUPPLY VOLTAGE TO FEEDBACK THROUGH THE RESISTOR TO GROUND, NOT DRAWING ENOUGH CURRENT TO TRIP THE FUSE.
NHTSA ID: 10V645000
Component:
# of Units Affected: 26
Consequence Summary:
THIS WOULD CAUSE THE RESISTOR TEMPERATURE TO RISE TO A POINT WHERE IT WILL MELT AND POSSIBLY IGNITE THE PLASTIC BLOWER HOUSING TO WHICH IT IS MOUNTED. THE OVERHEATING CAN RESULT IN A FIRE.
Corrective Action:
CORP. MICRO BIRD IN COOPERATION WITH TRANS/AIR WILL INSTALL A THERMAL SHUTDOWN DEVICE IN SERIES WITH THE SPEED RESISTORS. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JANUARY 11, 2011. OWNERS MAY CONTACT TRANS/AIR WARRANTY AND SERVICE CENTER AT 1-800-673-2446.
Park Outside Advisory: No
Do not Drive Advisory: No
December 21, 2010
(Campaign #: 10-040-ACU)

TRANS/AIR TA-73 EVAPORATOR/OVERHEATS

CORP. MICRO BIRD IS RECALLING CERTAIN MODEL YEAR 1999 THROUGH 2001 GIRARDIN MB II AND MB IV SCHOOL BUSES BUILT ON FORD AND GM CUTAWAY CHASSIS FROM AUGUST 2, 1999, THROUGH MAY 31, 2001, AND EQUIPPED WITH A TRANS/AIR TA73 EVAPORATOR. THE EVAPORATOR UTILIZES A POWER RESISTOR TO REGULATE BLOWER SPEED. SHOULD A SHORT OCCUR IN THE "LOW OR MEDIUM SPEED" CIRCUIT WHILE THE BLOWER IS IN HIGH SPEED, THE SHORT WILL CAUSE THE SUPPLY VOLTAGE TO FEEDBACK THROUGH THE RESISTOR TO GROUND, NOT DRAWING ENOUGH CURRENT TO TRIP THE FUSE.
NHTSA ID: 10V637000
Component:
# of Units Affected: 30
Consequence Summary:
THIS WOULD CAUSE THE RESISTOR TEMPERATURE TO RISE TO A POINT WHERE IT WILL MELT AND POSSIBLY IGNITE THE PLASTIC BLOWER HOUSING TO WHICH IT IS MOUNTED. THE OVERHEATING CAN RESULT IN A FIRE.
Corrective Action:
CORP. MICRO BIRD IN COOPERATION WITH TRANS/AIR WILL INSTALL A THERMAL SHUTDOWN DEVICE IN SERIES WITH THE SPEED RESISTORS. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JANUARY 11, 2011. OWNERS MAY CONTACT TRANS/AIR WARRANTY AND SERVICE CENTER AT 1-800-673-2446.
Park Outside Advisory: No
Do not Drive Advisory: No
December 15, 2010
(Campaign #: 10-039-JSU)

JOINT STRENGTH

CORP. MICRO BIRD IS RECALLING MODEL YEAR 2008 AND 2009 GIRARDIN G5 SCHOOL BUSES BUILT ON GM AND FORD CUTAWAY CHASSIS FROM FEBRUARY 1, 2008 THROUGH DECEMBER 16, 2008. THE SHEET METAL BELOW THE WINDOW INSIDE THE BUS ON THE LEFT-HAND SIDE FAILS TO COMPLY WITH THE JOINT STRENGTH REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 221, "SCHOOL BUS BODY JOINT STRENGTH." THERE IS NO ADHESIVE ON THE JOINT BETWEEN THE TWO EMBOSSED ALUMINUM SHEETS.
NHTSA ID: 10V627000
Component: STRUCTURE
# of Units Affected: 112
Consequence Summary:
IN THE EVENT OF A CRASH, THE EMBOSSED ALUMINUM SHEET MAY SEPARATE FROM THE INTERIOR COMPARTMENT STRUCTURE AND CAUSE INJURY TO BUS PASSENGERS.
Corrective Action:
DEALERS WILL REPAIR THE BUSES BY ADDING ADHESIVE AND RIVETS BETWEEN THE 2 EMBOSSED ALUMINUM SHEETS FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JANUARY 5, 2011. OWNERS MAY CONTACT CORP. MICRO BIRD AT 1-819-477-2021.
Park Outside Advisory: No
Do not Drive Advisory: No
August 13, 2010
(Campaign #: 10-038-WIU)

T-SLIDER OR PANORAMIC PUSH-OUT WINDOW

CERTAIN GIRARDIN MODEL YEAR 2006 THROUGH 2010 AND MICRO BIRD BY GIRARDIN MODEL YEAR 2009 THROUGH 2010 G5 AND 2003 THROUGH 2006 GIRARDIN MB IV TRANSIT BUSES FAIL TO CONFORM TO THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 217, "BUS EMERGENCY EXISTS AND WINDOW RETENTION AND RELEASE." THE VEHICLES ARE EQUIPPED WITH THERMAL T-SLIDER OR PANORAMIC TYPE PUSH-OUT WINDOWS WITH 2 RELEASE MECHANISMS (ONE ON EACH SIDE). THE WINDOW HANDLE BASE SPACER PLATE CAN TEAR DUE TO THE ROTATION OF THE EXTERIOR WINDOW FRAME.
NHTSA ID: 10V377000
Component:
# of Units Affected: 130
Consequence Summary:
IN THE EVENT OF A CRASH, THE EMERGENCY EXIT COULD NOT SUFFICIENTLY RESTRAIN THE OCCUPANT(S) OR BECOME INOPERABLE. THE OCCUPANT(S) COULD BE THROWN FROM THE VEHICLE OR NOT BE CAPABLE OF OPENING THE EMERGENCY EXITS WHICH COULD CAUSE INJURY OR DEATH OF THE VEHICLE OCCUPANT(S).
Corrective Action:
GIRARDIN WILL NOTIFY OWNERS AND WILL PROVIDE PARTS TO PERFORM THE REPAIR ALONG WITH INSTRUCTIONS FREE OF CHARGE. THE SAFETY RECALL BEGAN ON OCTOBER 8, 2010. OWNERS MAY CONTACT MICRO BIRD AT 1-819-477-2012.
Park Outside Advisory: No
Do not Drive Advisory: No
March 25, 2010
(Campaign #: 10-036-RIU)

WHEELCHAIR LIFTS/INTERLOCK BELT

CORP. MICRO BIRD HAS NOTIFIED NHTSA ABOUT A DEFECT IN CERTAIN MODEL YEAR 2007 THROUGH 2010 SCHOOL BUSES MANUFACTURED BETWEEN DECEMBER 2007 AND MARCH 2010 FITTED WITH RICON PUBLIC USE S AND K SERIES WHEELCHAIR LIFTS. THE RESTRAINT BELT ON THESE LIFTS WAS DESIGNED TO PREVENT THE LIFT FROM MOVING, UNLESS THE TONGUE OF THE BELT IS FULLY ENGAGED AND LATCHED IN THE BUCKLE. RICON HAS DISCOVERED, HOWEVER, THAT IT IS POSSIBLE FOR THE OPERATOR TO INSERT THE BELT TONGUE INTO THE BUCKLE WITHOUT FULLY ENGAGING THE LATCHING MECHANISM. IN THIS CASE, THE RESTRAINT BELT WOULD APPEAR TO BE LATCHED, AND THE OPERATOR COULD RUN THE LIFT. IF THE RESTRAINT BELT TONGUE IS NOT FULLY ENGAGED INTO THE RESTRAINT BELT BUCKLE, AND LATCHED, THE LIFT MAY OPERATE WITH AN OCCUPANT ON THE PLATFORM.
NHTSA ID: 10V121000
Component:
# of Units Affected: 103
Consequence Summary:
THE USER OF THE LIFT COULD BE INJURED SHOULD THE LIFT MOVE WITHOUT THE RESTRAINT BELT PROPERLY BUCKLED.
Corrective Action:
MICRO BIRD IS WORKING WITH RICON AND RICON WILL BE HANDLING THE REMEDY FOR THIS CAMPAIGN. PLEASE SEE RICON'S DEFECT REPORT 09E-060. RICON WILL PROVIDE CUSTOMERS WITH A WARNING DECAL AND A DVD-BASED TRAINING AID. THE SAFETY RECALL BEGAN ON M,ARCH 31, 2010. OWNERS MAY CONTACT RICON AT 1-818-267-3000 OR MICRO BIRD AT 1-819-477-2012.
Park Outside Advisory: No
Do not Drive Advisory: No
March 25, 2010
(Campaign #: 10-037-RIU)

WHEELCHAIR LIFTS/UP BUTTON

CORP. MICRO BIRD HAS NOTIFIED NHTSA ABOUT A DEFECT IN CERTAIN MODEL YEAR 2009 AND 2010 SCHOOL BUSES MANUFACTURED BETWEEN OCTOBER 2008 AND MARCH 2010 FITTED WITH RICON PUBLIC USE S AND K SERIES WHEELCHAIR LIFTS. DUE TO A PROBLEM IN THE SOFTWARE THAT CONTROLS THE LIFTS UP FUNCTION, IF THE SWITCH IS RELEASED BEFORE THE FLOOR LEVEL LIMIT SWITCH IS ACTIVATED, THE LIFT MAY CONTINUE ITS UPWARD TRAVEL FOR APPROXIMATELY 1 SECOND BEFORE STOPPING. THE CONTINUED UPWARD TRAVEL MAY OVERRUN THE FLOOR LEVEL CUT OFF POINT.
NHTSA ID: 10V123000
Component:
# of Units Affected: 49
Consequence Summary:
WHEN THE PLATFORM OVERRUNS THE VEHICLE FLOOR LEVEL AND STOPS AT AN ANGLE FROM 15-20 DEGREES, IT IS POSSIBLE FOR A PERSON IN A WHEELCHAIR TO TIP OVER AND FOR SOMEONE STANDING ON THE PLATFORM TO FALL, POSSIBLY RESULTING IN INJURIES.
Corrective Action:
CORP. MICRO BIRD WILL NOTIFY OWNERS AND THE REPAIRS WILL BE PERFORMED BY AUTHORIZED RICON DEALERS FREE OF CHARGE. CURRENTLY RICON IS DEVELOPING A SOFTWARE SOLUTION AND IS NOT AVAILABLE. UNTIL THE SOFTWARE SOLUTION IS AVAILABLE, RICON WILL PROVIDE OWNERS WITH A BULLETIN OUTLINING PROPER WHEELCHAIR LIFT OPERATION AND WILL SHIP OWNERS A DVD-BASED TRAINING AID TO PROMOTE PROPER LIFT OPERATION AT NO COST. THE SAFETY RECALL BEGAN ON APRIL 1, 2010. OWNERS MAY CONTACT RICON AT 1-818-267-3000 OR MICRO BIRD AT 1-819-477-2012.
Park Outside Advisory: No
Do not Drive Advisory: No
February 25, 2010
(Campaign #: 10-035-SEU)

SEATS

CORP. MICRO BIRD, INC. HAS NOTIFIED NHTSA ABOUT A NONCOMPLIANCE IN CERTAIN MODEL YEAR 2006 THROUGH 2010 G5 SCHOOL BUSES MANUFACTURED FROM JUNE 1, 2006 AND FEBRUARY 15, 2009, EQUIPPED WITH 39 OR 45 INCH SEATS. THE BUSES FAIL TO CONFORM TO THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 222, "SCHOOL BUS PASSENGER SEATING AND CRASH PROTECTION." SOME SEATS WERE INSTALLED WITHOUT ANY REINFORCEMENT UNDER THE FLOOR.
NHTSA ID: 10V067000
Component:
# of Units Affected: 582
Consequence Summary:
IN THE EVENT OF A CRASH, THE SEAT MAY NOT ABSORB SUFFICIENT ENERGY TO RESTRAIN THE OCCUPANT AS INTENDED AND IT COULD RESULT IN INJURY OR DEATH TO THE OCCUPANT.
Corrective Action:
MICRO BIRD WILL NOTIFY OWNERS AND DEALERS WILL REPAIR THE BUSES FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JUNE 29, 2010. OWNERS MAY CONTACT MICRO BIRD AT 1-819-477-2012.
Park Outside Advisory: No
Do not Drive Advisory: No