Braun Industries, Inc.: Safety Recalls in 2021
Updated on March 19, 2026.
There were 3 safety recalls made by Braun Industries, Inc. in 2021. See the details of the recalls below.
You can also see similar information for other manufacturers.
Data Source: NHTSA.
September 23, 2021
(Campaign #: NR (Not Reported))
Damaged Wires and Oxygen Tube May Cause Fire
Braun Ambulances is recalling certain 2020 Demers Ambulances MXP153 Ford F-Series Gas, MXP153 Dodge Ram, and 2020-2021 MXP153 Ford F-Series Diesel emergency vehicles. The medical oxygen tube and electrical wires may become damaged due to insufficient clearance from the ceiling spacers.
NHTSA ID: 21V740000
Component: EQUIPMENT
# of Units Affected: 9
Consequence Summary:
Damage to the wires and medical oxygen tube increases the risk of a fire.
Corrective Action:
Dealers will remove the ceiling panels and spacers, replace wires and oxygen network tubing, and create a routing channel inside the insulation board for all wires, free of charge. Owner letters were mailed on October 6, 2021. Owners may contact Braun Ambulances' customer service at 1-877-344-9990.
Park Outside Advisory: No
Do not Drive Advisory: No
Completion Rate (%): 100
March 17, 2021
(Campaign #: NR (Not Reported))
Seat Locking Pin Assembly May Fail/FMVSS 207 & 210
Braun Ambulances is recalling certain 2019 and 2021 MX170E Ford E-Series, and 2019-2020 MXP170E Dodge Ram 5500 Demers Ambulance vehicles equipped with a sliding attendant seat on the passenger-side of the ambulance patient compartment. The locking pin assembly in the sliding attendant seat may fail under certain loading conditions. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) numbers 207, "Seating Systems" and 210, "Seat Belt Assembly Anchorages."
NHTSA ID: 21V183000
Component:
# of Units Affected: 12
Consequence Summary:
If the locking pin fails, the occupant may not be sufficiently restrained during a crash, increasing the risk of an injury.
Corrective Action:
Braun will notify owners and dealers will replace the locking pin assembly, free of charge. The recall began on April 2, 2021. Owners may contact Braun Ambulances customer service at 1-877-344-9990.
Park Outside Advisory: No
Do not Drive Advisory: No
Completion Rate (%): 100
January 8, 2021
(Campaign #: NR (Not Reported))
D-Ring Installed Too Close To Mounting Flange
Braun Ambulances (Braun) is recalling certain 2019 and 2021 Crestline CCL150 Type III E-Series and 2019-2020 Crestline CCL150 Type I F-Series and CCL150 Type III G-Series ambulances. Two of the eight fastening points of the seat belt system installed in the ambulance patient compartment side-facing CPR seating position on the street-side of the vehicle may be defective. Two of the threaded inserts used for the rearward retractor and shoulder belt D-ring are installed too close to a mounting flange resulting in improper crimping of the threaded insert.
NHTSA ID: 21V003000
Component:
# of Units Affected: 61
Consequence Summary:
The improper crimping may result in partial or complete loss of effectiveness of the seat belt harness, increasing the risk of injury to the occupant in that seated position, in the event of a crash.
Corrective Action:
Braun will notify owners and dealers will inspect both seat belt anchor points and if no defect exists, no further action will be required. If the inspection shows the defect exists on one or both seat belt anchor points, your dealer will replace the defective insert(s) with nut plate(s) during the inspection, free of charge. The recall began on March 1, 2021. Owners may contact Braun Ambulances customer service at 1-877-344-9990.
Park Outside Advisory: No
Do not Drive Advisory: No
Completion Rate (%): 100